LuDong Mine Machinery Co., Ltd.

Mobile: 86-13589789857

 

PRODUCT CENTER

NEWS

SERVICE

Ludong News

Industry Trends

Knowledge

 

 

 

 

 

 

 

 

 

Tel:+86-535-8117966   Phone:+86-13589789857(Mr Cao)    E-mail: ldkuangji@163.com    Add: No. 189, Zhaojin Road, Zhaoyuan City, Shandong Province, China

Copyright © LuDong Mine Machinery Co., Ltd.          鲁ICP备09077777号-1      Powered by:300.cn

 

ABOUT US

Product center

FX type hydrocyclone

Product name:

FX type hydrocyclone

浏览量
所属分类
Classifying equipment
Description:
A hydrocyclone is a device that uses centrifugal force to classify a slurry. There are no sports, power components, and the corresponding mud pump is required.
Application range:
Widely used in oil extraction, grading operations in the grading process of colored, black and non-metallic concentrators
Applicable material:
It is used for desliming and dewatering of slurry materials, and is one of the important equipments such as sand removal, desilting equipment, mine classification, treatment of coal slurry water in coal preparation plant and recovery of coal slurry.
我要询价
Advantage
Principle
Parameters
Case

  Advantage characteristics:

  The hydrocyclone equipment has low cost, easy assembly and disassembly, and has small floor space and low capital construction costs. The unit volume processing capacity is large, the classification granularity is fine, the classification efficiency is high, the amount of DC and the time of the slurry in the cyclone are small, and the shutdown is easy to handle.

  The machine has high classification efficiency. It is used as the slurry classification of grinding circuit. Usually, multiple parallel combined units are selected. The classification fineness and treatment capacity are greatly affected by the diameter of the upper cylinder, the inlet pressure of the slurry and the concentration of the slurry, and the process fluctuation is large.

  working principle:

  The cyclone is a conical container with a cylindrical portion, and the inner conical portion of the cone is called a liquid chamber. There is a liquid inlet tube outside the cone, which communicates with the liquid chamber in a tangential direction. The top of the container is the overflow port and the bottom is the bottom port (also called the discharge port). A hollow circular tube extends from the top to the liquid chamber along the axis of the cyclone. This tube is called an overflow tube, also called a swirling director. An overflow passage formed therein to allow the mud to overflow. The size of the cyclone is determined by the largest inner diameter of the cone.

  Under the action of the swirling flow, the mud creates a low pressure zone in the middle of the cone, forming a gas column, causing a vacuum, which acts as a suction, discharges the light mud from the upper port, and the heavy particles smash toward the barrel wall and slide down the barrel wall. The mouth is discharged.

  Technical Parameters:

FX type hydrocyclone technical parameter list

specification

Internal meridian (mm)

Feeding caliber (mm)

Overflow pipe diameter (mm)

Sinking caliber (mm)

Cone angle(°)

Maximum feed size (mm)

Feed pressure (Mpa)

Processing capacity (m/h)

Separation particle size (M)

Dimensions (mm)

Stand-alone weight (kg)

FX-660

660

187,167

180,200,220,240

80,110,150

20

16

0.03-0.4

250-360

74-220

215

850

2720

950

FX-500

500

130        120

130,140,160,180,220

135,45,50,65

25

10

0.03-0.4

140-220

74-220

951

718

1825

416

 

 

 

 

 

20

 

 

 

74-220

850

623

1825

490

 

 

 

 

 

10

 

 

 

74-220

951

718

2280

556

FX-350

350

80

80,90,105,115,120

 70,80,90,100

25

6

0.03-0.4

60-105

50-150

530

413

1411

135

 

 

 

 

 

20

 

 

 

50-150

530

413

1411

155

 

 

 

 

 

15

 

 

 

50-120

530

413

1674

230

FX-300

300

64           75

65,80,100,120

30,35,40,45

20

5

0.05-0.4

45-90

50-15

530

410

1305

88

 

 

 

 

 

15

 

 

 

40-100

563

410

1490

169

FX-250

250

55,74,80

65,80,100,120

50,60,70

20

3

0.05-0.4

40-65

40-100

563

534

1178

63

 

 

 

 

 

15

 

 

 

40-100

548

390

1057

120

 

 

 

 

 

10

 

 

 

30-100

548

415

1380

123

FX-200

200

48

40,50,55,65

20,25,30,35,40

20

2

0.05-0.4

25-40

40-100

548

307

1025

36

 

 

 

 

 

15

 

 

 

30-100

320

307

1114

64

FX-150

150

36

30,35,40,45

16,18,20,25,30,35,40,

20

1.5

0.05-0.4

11-20

30-74

320

270

682

22

 

 

 

 

 

15

 

 

 

30-74

252

349

899

20

 

 

 

 

 

8

 

 

 

20-74

290

295

1267

60

FX-125

125

26

25,30,35,40

16,20,24,28,32

17

1

0.05-0.4

8-15

20-100

280

185

617

10

 

 

 

 

 

8

 

 

 

20-74

210

240

973

12

FX-100

100

23

20,25,30,40

 8,10,12,14

20

1

0.05-0.4

5-12

20-100

250

210

525

8

 

 

 

 

 

15

 

 

 

10-100

257

210

575

5

 

 

 

 

 

8

 

 

 

10-74

257

210

829

6

FX-75

75

13

15,17,20

16,18,20,22

15

0.6

0.1-0.5

2-5

20-74

240

230

459

4

 

 

 

 

 

7

 

 

 

5-40

240

230

700

7

FX-50

50

9

11,13,15,18

8,10,12,14,16,18

15

0.3

0.1-0.5

1.5-3

10-74

160

152

325

2

 

 

 

 

 

6

 

 

 

5-30

160

152

550

2.5

FX-25

25

5

5,6,7,8

 8,10,12,14,16,18

5

0.2

0.1-0.5

0.3-1

3-10

160

152

587

0.8

 

 

 

 

 

3

 

 

 

2-10

120

110

576

1.4

FX-10

10

2

2,3,4

6,7,8,10,12

4

1

0.1-0.1

0.05-1

1-5

60

34

140

0.5

 

  working principle:

  The cyclone is a conical container with a cylindrical portion, and the inner conical portion of the cone is called a liquid chamber. There is a liquid inlet tube outside the cone, which communicates with the liquid chamber in a tangential direction. The top of the container is the overflow port and the bottom is the bottom port (also called the discharge port). A hollow circular tube extends from the top to the liquid chamber along the axis of the cyclone. This tube is called an overflow tube, also called a swirling director. An overflow passage formed therein to allow the mud to overflow. The size of the cyclone is determined by the largest inner diameter of the cone.

  Under the action of the swirling flow, the mud creates a low pressure zone in the middle of the cone, forming a gas column, causing a vacuum, which acts as a suction, discharges the light mud from the upper port, and the heavy particles smash toward the barrel wall and slide down the barrel wall. The mouth is discharged.

  Advantage characteristics:

  The hydrocyclone equipment has low cost, easy assembly and disassembly, and has small floor space and low capital construction costs. The unit volume processing capacity is large, the classification granularity is fine, the classification efficiency is high, the amount of DC and the time of the slurry in the cyclone are small, and the shutdown is easy to handle.

  The machine has high classification efficiency. It is used as the slurry classification of grinding circuit. Usually, multiple parallel combined units are selected. The classification fineness and treatment capacity are greatly affected by the diameter of the upper cylinder, the inlet pressure of the slurry and the concentration of the slurry, and the process fluctuation is large.

  Technical Parameters:

FX type hydrocyclone technical parameter list

specification

Internal meridian (mm)

Feeding caliber (mm)

Overflow pipe diameter (mm)

Sinking caliber (mm)

Cone angle(°)

Maximum feed size (mm)

Feed pressure (Mpa)

Processing capacity (m/h)

Separation particle size (M)

Dimensions (mm)

Stand-alone weight (kg)

FX-660

660

187,167

180,200,220,240

80,110,150

20

16

0.03-0.4

250-360

74-220

215

850

2720

950

FX-500

500

130        120

130,140,160,180,220

135,45,50,65

25

10

0.03-0.4

140-220

74-220

951

718

1825

416

 

 

 

 

 

20

 

 

 

74-220

850

623

1825

490

 

 

 

 

 

10

 

 

 

74-220

951

718

2280

556

FX-350

350

80

80,90,105,115,120

 70,80,90,100

25

6

0.03-0.4

60-105

50-150

530

413

1411

135

 

 

 

 

 

20

 

 

 

50-150

530

413

1411

155

 

 

 

 

 

15

 

 

 

50-120

530

413

1674

230

FX-300

300

64           75

65,80,100,120

30,35,40,45

20

5

0.05-0.4

45-90

50-15

530

410

1305

88

 

 

 

 

 

15

 

 

 

40-100

563

410

1490

169

FX-250

250

55,74,80

65,80,100,120

50,60,70

20

3

0.05-0.4

40-65

40-100

563

534

1178

63

 

 

 

 

 

15

 

 

 

40-100

548

390

1057

120

 

 

 

 

 

10

 

 

 

30-100

548

415

1380

123

FX-200

200

48

40,50,55,65

20,25,30,35,40

20

2

0.05-0.4

25-40

40-100

548

307

1025

36

 

 

 

 

 

15

 

 

 

30-100

320

307

1114

64

FX-150

150

36

30,35,40,45

16,18,20,25,30,35,40,

20

1.5

0.05-0.4

11-20

30-74

320

270

682

22

 

 

 

 

 

15

 

 

 

30-74

252

349

899

20

 

 

 

 

 

8

 

 

 

20-74

290

295

1267

60

FX-125

125

26

25,30,35,40

16,20,24,28,32

17

1

0.05-0.4

8-15

20-100

280

185

617

10

 

 

 

 

 

8

 

 

 

20-74

210

240

973

12

FX-100

100

23

20,25,30,40

 8,10,12,14

20

1

0.05-0.4

5-12

20-100

250

210

525

8

 

 

 

 

 

15

 

 

 

10-100

257

210

575

5

 

 

 

 

 

8

 

 

 

10-74

257

210

829

6

FX-75

75

13

15,17,20

16,18,20,22

15

0.6

0.1-0.5

2-5

20-74

240

230

459

4

 

 

 

 

 

7

 

 

 

5-40

240

230

700

7

FX-50

50

9

11,13,15,18

8,10,12,14,16,18

15

0.3

0.1-0.5

1.5-3

10-74

160

152

325

2

 

 

 

 

 

6

 

 

 

5-30

160

152

550

2.5

FX-25

25

5

5,6,7,8

 8,10,12,14,16,18

5

0.2

0.1-0.5

0.3-1

3-10

160

152

587

0.8

 

 

 

 

 

3

 

 

 

2-10

120

110

576

1.4

FX-10

10

2

2,3,4

6,7,8,10,12

4

1

0.1-0.1

0.05-1

1-5

60

34

140

0.5

 

  The machine has high classification efficiency. It is used as the slurry classification of grinding circuit. Usually, multiple parallel combined units are selected. The classification fineness and treatment capacity are greatly affected by the diameter of the upper cylinder, the inlet pressure of the slurry and the concentration of the slurry, and the process fluctuation is large.

  Technical Parameters:

FX type hydrocyclone technical parameter list

specification

Internal meridian (mm)

Feeding caliber (mm)

Overflow pipe diameter (mm)

Sinking caliber (mm)

Cone angle(°)

Maximum feed size (mm)

Feed pressure (Mpa)

Processing capacity (m/h)

Separation particle size (M)

Dimensions (mm)

Stand-alone weight (kg)

FX-660

660

187,167

180,200,220,240

80,110,150

20

16

0.03-0.4

250-360

74-220

215

850

2720

950

FX-500

500

130        120

130,140,160,180,220

135,45,50,65

25

10

0.03-0.4

140-220

74-220

951

718

1825

416

 

 

 

 

 

20

 

 

 

74-220

850

623

1825

490

 

 

 

 

 

10

 

 

 

74-220

951

718

2280

556

FX-350

350

80

80,90,105,115,120

 70,80,90,100

25

6

0.03-0.4

60-105

50-150

530

413

1411

135

 

 

 

 

 

20

 

 

 

50-150

530

413

1411

155

 

 

 

 

 

15

 

 

 

50-120

530

413

1674

230

FX-300

300

64           75

65,80,100,120

30,35,40,45

20

5

0.05-0.4

45-90

50-15

530

410

1305

88

 

 

 

 

 

15

 

 

 

40-100

563

410

1490

169

FX-250

250

55,74,80

65,80,100,120

50,60,70

20

3

0.05-0.4

40-65

40-100

563

534

1178

63

 

 

 

 

 

15

 

 

 

40-100

548

390

1057

120

 

 

 

 

 

10

 

 

 

30-100

548

415

1380

123

FX-200

200

48

40,50,55,65

20,25,30,35,40

20

2

0.05-0.4

25-40

40-100

548

307

1025

36

 

 

 

 

 

15

 

 

 

30-100

320

307

1114

64

FX-150

150

36

30,35,40,45

16,18,20,25,30,35,40,

20

1.5

0.05-0.4

11-20

30-74

320

270

682

22

 

 

 

 

 

15

 

 

 

30-74

252

349

899

20

 

 

 

 

 

8

 

 

 

20-74

290

295

1267

60

FX-125

125

26

25,30,35,40

16,20,24,28,32

17

1

0.05-0.4

8-15

20-100

280

185

617

10

 

 

 

 

 

8

 

 

 

20-74

210

240

973

12

FX-100

100

23

20,25,30,40

 8,10,12,14

20

1

0.05-0.4

5-12

20-100

250

210

525

8

 

 

 

 

 

15

 

 

 

10-100

257

210

575

5

 

 

 

 

 

8

 

 

 

10-74

257

210

829

6

FX-75

75

13

15,17,20

16,18,20,22

15

0.6

0.1-0.5

2-5

20-74

240

230

459

4

 

 

 

 

 

7

 

 

 

5-40

240

230

700

7

FX-50

50

9

11,13,15,18

8,10,12,14,16,18

15

0.3

0.1-0.5

1.5-3

10-74

160

152

325

2

 

 

 

 

 

6

 

 

 

5-30

160

152

550

2.5

FX-25

25

5

5,6,7,8

 8,10,12,14,16,18

5

0.2

0.1-0.5

0.3-1

3-10

160

152

587

0.8

 

 

 

 

 

3

 

 

 

2-10

120

110

576

1.4

FX-10

10

2

2,3,4

6,7,8,10,12

4

1

0.1-0.1

0.05-1

1-5

60

34

140

0.5

 

  working principle:

  The cyclone is a conical container with a cylindrical portion, and the inner conical portion of the cone is called a liquid chamber. There is a liquid inlet tube outside the cone, which communicates with the liquid chamber in a tangential direction. The top of the container is the overflow port and the bottom is the bottom port (also called the discharge port). A hollow circular tube extends from the top to the liquid chamber along the axis of the cyclone. This tube is called an overflow tube, also called a swirling director. An overflow passage formed therein to allow the mud to overflow. The size of the cyclone is determined by the largest inner diameter of the cone.

  Under the action of the swirling flow, the mud creates a low pressure zone in the middle of the cone, forming a gas column, causing a vacuum, which acts as a suction, discharges the light mud from the upper port, and the heavy particles smash toward the barrel wall and slide down the barrel wall. The mouth is discharged.

  Advantage characteristics:

  The hydrocyclone equipment has low cost, easy assembly and disassembly, and has small floor space and low capital construction costs. The unit volume processing capacity is large, the classification granularity is fine, the classification efficiency is high, the amount of DC and the time of the slurry in the cyclone are small, and the shutdown is easy to handle.

上一篇